Egis Enterprises · Technical Datasheet
Egis PureSlide L80
Life-Science / Clean-Room Doors
Double-leaf hygienic automatic sliding door for labs and clean production.
Double-leaf hygienic sliding door for laboratories and clean production areas that need wide, hands-free openings.
Specifications
| Door Type | Double-leaf hygienic sliding door |
|---|---|
| Operation | Automatic, touchless activation |
| Leaf Thickness Mm | 80 mm |
| Clear Opening | 1200-2400 mm W x 2100-2600 mm H |
| Finish | HPL / powder coat / stainless steel; antibacterial option |
| Airtightness | Full-perimeter gasketing on closing |
| Opening Speed M S | 0.4 - 0.8 |
| Automation | Quiet microprocessor drive, touchless sensors |
| Safety | EN 16005 safety photocell, presence detection, battery backup |
| Options | Pressure-differential interlock, lead lining, flush track |
| Certifications | CE marked, Declaration of Conformity |
Overview
Where the PureSwing covers personnel doors, the PureSlide L80 covers traffic: a double-leaf hygienic automatic sliding door for laboratories, clean production areas and pharma corridors where hands are gloved, trolleys are moving, and nobody should touch a door. The 80 mm double leaves open touchlessly to a clear width of 1200 to 2400 mm — wide enough for equipment and bed/trolley transfer.
The leaves are hygienic throughout: HPL, powder coat or full stainless steel faces with an antibacterial option, flush and sealed, gasketed on closing around the full perimeter. The drive is a quiet microprocessor unit — noise matters in labs and clean production — with touchless activation and safety to EN 16005. Double-leaf geometry means each leaf travels half the distance, so the wide opening cycles as fast as a narrow single door.
Egis supplies the L80 as a complete automatic system for Indian life-science facilities: leaves, frame, track, drive, activation and safety, installed and commissioned. It interlocks for airlock duty and steps aside to the HermaSeal range where true hermetic (Class 4) sealing is required.
Why double-leaf for clean traffic
A single leaf covering a 2400 mm opening must travel 2400 mm — slow, heavy, and hard on the drive. Two 1200 mm leaves each travel 1200 mm: the opening clears in half the time with half the moving mass per leaf, and the drive works well within its rating for a long service life. For clean facilities this speed matters twice: less open time means less pressure-cascade disturbance, and faster cycles mean traffic doesn't queue at the door.
The perimeter gasketing closes on the meeting stiles as well as the frame — the centre meeting point is the seal detail that separates a hygienic sliding door from a partition slider. Touchless activation (radar/infrared) keeps gloved hands off the leaf, and the quiet drive avoids the acoustic disturbance that cheap operators inflict on lab environments.
- Double-leaf automatic sliding; 1200–2400 mm clear width
- 80 mm hygienic leaves: HPL / powder coat / stainless; antibacterial option
- Full-perimeter gasketing including centre meeting stiles
- Quiet microprocessor drive, 0.4–0.8 m/s, touchless activation
- Safety to EN 16005; interlocks in airlock configurations
- HermaSeal upgrade path where Class 4 hermetic sealing is required
Typical applications
Pharma production corridors
Wide touchless openings for material and personnel flow in classified areas.
Laboratories
Quiet automatic doors for lab suites and instrument rooms.
Clean packaging areas
Hygienic high-cycle doors for clean packaging halls.
Hospital clean zones
Touchless transfer doors for CSSD, pharmacy and sterile corridors.
FAQs
When do I need the PureSlide L80 instead of the PureSwing P60?
When the opening is wide (over 1200 mm), traffic is frequent or hands-free operation is required — trolleys, gloved hands, high cycle counts. The P60 is the economical hygienic choice for standard personnel doors; the L80 is the traffic door.
Is the L80 airtight like the HermaSeal?
It is gasketed and seals well — suitable for maintaining pressure cascades in Grade C/D and general clean areas — but it is not a Class 4 hermetic door. Where the room needs true hermetic sealing (operating theatres, Grade B, isolation), specify the HermaSeal S100 or S200 Pro.
How does touchless activation work?
Radar detects approaching traffic and infrared presence sensors keep the door open while the opening is occupied. No handles, no push plates — nothing to touch with gloved or contaminated hands, and nothing to become a cross-contamination point.
Is the drive noisy?
No — the L80 uses a quiet microprocessor drive specified for lab and clean-production environments, with soft start/stop. Acoustic disturbance is a common complaint with cheap operators; it is a design input here.
Can it be used in an airlock?
Yes, interlocked for one-door-open airlock logic with status indication.
What maintenance is needed?
Track and carrier checks, gasket inspection, sensor function tests and drive diagnostics on cycle count. The touchless sensors need their lenses kept clean — a 30-second wipe during routine cleaning.